When it comes to replacing the glazing on your VELUX window, there are several options and while they’re all quick enough, we highlight the key methods
A straightforward and easy way of improving the energy efficiency, acoustics and appearance of your VELUX roof window is to look at VELUX replacement glass, with this opening up a number of possibilities in the process.
Whether it’s a repair job – for example, for chipped, broken or dirty windows – or whether you just want a better spec for your window, the use of a VELUX replacement glazing and a VELUX conversion kit (if necessary) can easily solve these issues.
Also, for those who have VELUX windows manufactured before April 2001, upgrading to opaque glazing can make a huge difference as not only will it boost performance, but they will also offer noise reduction and give you a laminated finish.
Here are some of the options available to you that can really reinvigorate your window.
0073
Laminated Glazing
In its simplest form, VELUX 0073 glazing keeps heat in from the sun to reduce energy costs and also increase your indoor safety. It is made up of a laminated inner pane, while there are foils for safety and a 4mm toughened outer pane for strength.
0060 Noise Reduction Glazing
If you feel your windows are quite loud, then the VELUX 0060 glazing is perhaps the best fit for you as it reduces outdoor noise even further, while also minimising the sound of rain and hail on the window.
It is made up of a laminated inner pane, in addition to a toughened external pane with sun protection coating and easy clean coating.
0034 Obscure Glazing
It can be difficult to find the right balance between privacy and letting natural light in, but the VELUX 0034 glazing does a fantastic job of doing both.
Made up of a laminated inner pane, it comes with white-coloured foils for privacy and a 4mm toughened external pane with extra heat insulation coating.
What you need to replace your glazing
If your VELUX window was manufactured before April 2001, in addition to the replacement glass, you will also need a conversion kit. Also, if your window is first, second or third generation, they will need replacing with a third-generation glazing.
Meanwhile, for all pre-2001 GHL top hung VELUX roof windows, you will need the specific IGR 4000 conversion kit to carry out the replacement.
In the event that you have a fourth generation VELUX window – which is conveniently identified by a K in the code – you will need fourth-generation glazing as a necessity.
If you are unsure as to what generation your VELUX window is, everything you need to know can be found on the delta plate, which is located in the right corner of the top sash. If you still can’t find it for whatever reason, then this guide here will help you identify it.
VELUX replacement glass is non-returnable, so as such, it’s imperative that you get your purchase right initially. To help you with that, we have put together a guide for you that’ll tell you exactly what glass and conversion kit you’ll need.
Replacing 1st Generation VELUX Glazing
Window Code
|
|
||||
---|---|---|---|---|---|
1st Gen | Conversion Kit | Replacement Glazing | |||
GGL - 1 | IGR 1 3000 | IPL M04 0073 / 0060 / 0034 | |||
GGL - 2 | IGR 2 3000 | IPL M08 0073 / 0060 / 0034 | |||
GGL - 3 | IGR 3 3000 | IPL P10 0073 / 0060 / 0034 | |||
GGL - 4 | IGR 4 3000 | IPL S06 0073 / 0060 / 0034 | |||
GGL - 5 | IGR 5 3000 | IPL 5 0073 / 0060 / 0034 | |||
GGL - 6 | IGR 6 3000 | IPL C04 0073 / 0060 / 0034 | |||
GGL - 7 | IGR 7 3000 | IPL U04 0073 / 0060 / 0034 | |||
GGL - 8 | IGR 8 3000 | IPL U08 0073 / 0060 / 0034 | |||
GGL -9 | IGR 9 3000 | IPL C01
0073 / 0034 |
|||
GGL - 10 | IGR 10 3000 | IPL S08
0073 / 0060 / 0034 |
|||
GGL - 11 | Call for Availability | IPL M12
0073 |
|||
GGL - 13 | Call for Availability | IPL M10
0073 / 0060 / 0034 |
|||
GGL - 14 | IGR 14 3000 | IPL M06
0073 / 0060 / 0034 |
Replacing 2nd Generation VELUX Glazing
Window Code
|
|
||||
---|---|---|---|---|---|
1st Gen | Conversion Kit | Replacement Glazing | |||
GGL 304 | IGR 304 3000 | IPL M04 0073 / 0060 / 0034 | |||
GGL 308 | IGR 308 3000 | IPL M08 0073 / 0060 / 0034 | |||
GGL 410 | IGR 410 3000 | IPL P10 0073 / 0060 / 0034 | |||
GGL 606 | IGR 606 3000 | IPL S06 0073 / 0060 / 0034 | |||
GGL 206 | N/A | IPL 206 0073 | |||
GGL 104 | IGR 104 3000 | IPL C04 0073 / 0060 / 0034 | |||
GGL 804 | IGR 804 3000 | IPL U04 0073 / 0060 / 0034 | |||
GGL 808 | IGR 808 3000 | IPL U08 0073
/ 0060 / 0034 |
|||
GGL 101 | IGR 101 3000 | IPL C01
0073 / 0034 |
|||
GGL 608 | IGR 608 3000 | IPL S08
0073 / 0060 / 0034 |
|||
GGL 312 | IGR 312 3000 | IPL M12
0073 |
|||
GGL 310 | IGR 310 3000 | IPL M10
0073 / 0060 / 0034 |
|||
GGL 306 | IGR 306 3000 | IPL M06
0073 / 0060 / 0034 |
Replacing 3rd Generation VELUX Glazing
Window Code
|
|
||||
---|---|---|---|---|---|
1st Gen | Conversion Kit | Replacement Glazing | |||
GGL M04 | Not Needed | IPL M04 0073
/ 0060 / 0034 |
|||
GGL M08 | Not Needed | IPL M08 0073
/ 0060 / 0034 |
|||
GGL P10 | Not Needed | IPL P10 0073
/ 0060 / 0034 |
|||
GGL S06 | Not Needed | IPL S06 0073
/ 0060 / 0034 |
|||
GGL F06 | Not Needed | IPL F06
0073 / 0060 / 0034 |
|||
GGL C04 | Not Needed | IPL C04 0073
/ 0060 / 0034 |
|||
GGL U04 | Not Needed | IPL U04 0073
/ 0060 / 0034 |
|||
GGL U08 | Not Needed | IPL U08 0073
/ 0060 / 0034 |
|||
GGL C01 | Not Needed | IPL C01
0073 / 0034 |
|||
GGL S08 | Not Needed | IPL S08
0073 / 0060 / 0034 |
|||
GGL M12 | Not Needed | IPL M12
0073 |
|||
GGL M10 | Not Needed | IPL M10
0073 / 0060 / 0034 |
|||
GGL M06 | Not Needed | IPL M06
0073 / 0060 / 0034 |
Installing my new glazing
While we do understand that some of you may be keen DIYers, we would strongly recommend and advise that you hire a professional window installer for the job, which is for a number of reasons.
The most important one is that should anything go wrong with the glazing due to it not being installed correctly, there is the possibility that the product’s guarantee may be voided as a result.
If you are unsure who to hire as an installer, it’s worth asking recommendations from friends, contacts or other tradespeople you know, or alternatively, the VELUX Group has a database just for its own installers. You can also get in touch with us and we can recommend an installer for you.